Automatic Stop Operation Check
Automatic stop operation check
1. Operate the motor at low speed.
2. Stop the motor operation anywhere except the off position by disconnecting terminal 5.
3. Connect terminals 1 and 5.
4. Connect the positive (+) lead from the battery to terminal 4 and ground terminal 3.
5. Check that the motor stops running at the off position.