A/T - Hydraulic Pressure Test
Group: TRANSAXLENumber: 01-40-003
Date: FEBRUARY, 2001
Model: 2001 MODELS
Subject:
2001 XG300, SANTA FE, SONATA & ELANTRA AUTOMATIC TRANSAXLE HYDRAULIC
PRESSURE TEST
DESCRIPTION:
1. This TSB provides hydraulic pressure test specifications in "psi" and "kPa" for the following shop manuals: 2001 XG300: Page TR-18, 2001 Santa Fe: Page TR-24, 2001 Elantra: Page TR-10, 2001 Sonata: Page AT-18.
2. STANDARD HYDRAULIC PRESSURE TEST: Warm up the engine until the automatic transaxle fluid temperature is 70°-100°C (158°-212°F). Connect the oil pressure gauge, P/N J34405, to the appropriate pressure port.
Pressure Ports:
2ND: Second brake pressure
UD: Underdrive clutch pressure
LR: Low & reverse brake pressure
DR: Damper clutch release pressure
RV: Reverse clutch pressure
OD: Overdrive clutch pressure
RED: Reduction brake pressure
3. Drive the vehicle under the driving conditions shown in the table while an assistant records the hydraulic pressure.
4. If the value is outside the standard range, refer to the Diagnosis Tables in the shop manuals: 2001 XG-300: Pages TR-19 & 20, 2001 Santa Fe: Pages TR-25 & 26, 2001 Elantra: Pages TR-11 & 12, 2001 Sonata, Pages 19 & 20.