Suction Hose/Line
SUCTION HOSENOTE
1. When installing each of the removed refrigerant lines, replace the O-ring (where applicable) at each fitting with new one and apply specified lubricant.
2. Observe the specified tightening torque at each fitting.
3. Be careful not to bend or twist refrigerant lines in order to install them easily.
4. After installation, evacuate, charge and test the air conditioning system.
1. Discharge refrigerant from the air conditioning system.
2. Disconnect evaporator side fitting of the suction hose. (12 mm nut, 1EA)
3. Disconnect compressor side fitting of the suction hose.
4. Remove the suction hose.
5. Installation is the reverse order of removal.