Recirculation Actuator Replacement
Recirculation Actuator Replacement
Removal Procedure
1. Remove the instrument panel (I/P) upper trim pad.
2. Disconnect the electrical connector from the recirculation actuator.
3. Remove the screws from the recirculation actuator (1).
4. Remove the recirculation actuator (1) from the HVAC module assembly (2).
Installation Procedure
1. Install the recirculation actuator (1) to the HVAC module assembly (2).
Notice: Refer to Fastener Notice.
2. Install the screws to the recirculation actuator (1).
Tighten the screws to 2 N.m (18 lb in).
3. Connect the electrical connector to the recirculation actuator.
4. Install the I/P upper trim pad.
5. Reprogram the recirculation actuator. Refer to Re-Calibrating Actuators. Programming and Relearning