Variable Valve Timing Solenoid: Service and Repair
Rocker Arm Oil Control Valve Removal/Installation
1. Remove the cowl cover and the under-cowl panel Service and Repair.
2. Disconnect the rocker arm oil control valve 2P connector (A) and the rocker arm oil pressure switch 2P connector (B).
3. Remove the bolts (C).
4. Remove the rocker arm oil control valve (D).
5. Install the parts in the reverse order of removal with a new rocker arm oil control valve filter (E).