DTC 15
DTC 15: A Short In The Evaporator Temperature Sensor Circuit1. Remove the evaporator temperature sensor.
2. Test the evaporator temperature sensor.
Is the resistance within the specifications shown on the graph?
YES - Go to step 3.
NO - Replace the evaporator temperature sensor.
3. Disconnect heater control panel connector B (22P).
4. Check for continuity between the No. 7 terminal of heater control panel connector B (22P) and body ground.
Is there continuity?
YES - Repair short to body ground in the wire between the heater control panel and the evaporator temperature sensor.
NO - Substitute a known-good heater control panel, and recheck. If the symptom/indication goes away, replace the original heater control panel.