Compressor Clutch Diode HVAC: Testing and Inspection
Diode Test:
NOTE: The diodes are designed to pass current in one direction while blocking it in the opposite direction. Most ohmmeters, unless equipped with a diode tester, should not be used to test diodes.
Check for continuity in both directions between the A and B terminals. There should be continuity in only one direction.