FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Mechanical Specifications




IGNITION TIMING

with service check connector jumped 15° ± 2° BTDC

DISTRIBUTOR

mounting bolt torque Value 18 Nm (13 ft.lb.)

SPARK PLUGS

gap 1.0 - 1.1 mm (0.039 - 0.043 in)
torque Value 18 Nm (13 ft-lb)

FIRING ORDER 1 3 4 2

CRANKSHAFT ROTATION

at pulley end counter clockwise