Evacuation of the Refrigerant System
Recovery/Recycling/Charging System:
Only use service equipment that is U.L.-listed and is certified to meet the requirements of SAE J221O to remove R-134a from the air conditioner system.
CAUTION: Exposure to air conditioner refrigerant and lubricant vapor or mist can irritate eyes, nose and throat. Avoid breathing the air conditioner refrigerant and lubricant vapor or mist.
If accidental system discharge occurs, ventilate work area before resuming service.
R-134a service equipment or vehicle air conditioner systems should not be pressure tested or leak tested with compressed air.
WARNING: Some mixture of air and R-134a have been shown to be combustible at elevated pressures and can result in fire or explosion causing injury or property damage. Never use compressed air to pressure test R-134a service equipment or vehicle air conditioner systems.
Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.
1. When an A/C System has been opened to the atmosphere, such as during installation or repair, it must be evacuated using a R-134a refrigerant Recovery/Recycling/Charging System. (If the system has been open for several days, the receiver/dryer should be replaced.)
2. Connect a R-134a refrigerant Recovery/Recycling/Charging System to the car as shown following the equipment manufacturer's instructions.
NOTE: If low pressure does not reach more than 27 in Hg (700 mm Hg) in 15 minutes, there is probably a leak in the system. Partially charge the system and check for leaks, refer to Heating and Air Conditioning/Testing and Inspection/Procedures.