FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Case Porosity Repair

1. Clean the leak area with solvent and air dry.

CAUTION: Epoxy cement may cause skin irritation and eye damage. Read and follow all information on the container label as provided by the manufacturer.

2. Mix a sufficient amount of epoxy cement GM P/N 1052533, or equivalent, following the manufacturer's recommendations.
3. When the transaxle case is hot, apply epoxy cement with a clean, dry soldering acid brush.
4. Allow the epoxy cement to cure for three hours before starting the engine.
5. Repeat fluid leak diagnosis procedure to verify the repair.