Forward Sensors
1. Deactivate airbag system as described under MAINTENANCE PROCEDURES/AIRBAG DEACTIVATION.
2. Disconnect battery ground cable.
3. Disconnect sensor connector from lamp support panel.
4. Remove CPA and sensor electrical connector.
5. Disconnect two sensor lead wire clamps and remove two sensor mounting bolts.
6. Remove sensor.
7. Reverse procedure to install, noting the following:
a. Install sensor with arrow pointing toward front of vehicle.
b. Torque mounting bolts to 98 inch lbs.
c. Following installation, activate airbag system as described under MAINTENANCE PROCEDURES/AIRBAG ACTIVATION.
d. Turn ignition switch to the On position and verify the ``Inflatable Restraint'' indicator flashes 7 to 9 times then turns Off. If indicator does not respond, refer to DIAGNOSIS AND TESTING PROCEDURE/TESTING PROCEDURES/RETRIEVING TROUBLE CODES.