Removal
REMOVAL
WARNING: Review safety precautions and warnings in this group before performing this procedure and . Failure to follow the warnings and cautions may result in serious or fatal injury.
NOTE: Typical A/C system service port and refrigerant line shown.
1. Remove the protective cap (1) from the service port (2).
2. Recover the refrigerant from the refrigerant system .
3. Using a Schrader-type valve core tool, remove the valve core (3) from the service port.
4. Install a plug in or tape over the opened service port(s).