Installation







INSTALLATION





1. Lubricate a new rubber grommet with clean washer fluid and install it into the washer fluid level switch mounting hole located in the forward-facing side of the washer reservoir (1). Always use a new rubber grommet seal on the reservoir.
2. Insert the nipple formation of the switch (2) through the rubber grommet seal in the reservoir.
3. Using hand pressure, press firmly and evenly on the switch body until the barbed nipple is fully seated in the rubber grommet seal in the reservoir. The flat edge of the switch body should be indexed to the flat molded into the reservoir.
4. Reconnect the vehicle wire harness connector for the washer fluid level switch to the switch connector receptacle.
5. Refill the washer reservoir with the washer fluid drained during removal.
6. Reconnect the battery negative cable.