Removal
REMOVAL
NOTE: Capture and properly store all fluid seepage in appropriately marked containers.
1. Disconnect the negative battery cable.
2. Disconnect the fuel quantity solenoid wiring harness connector.
3. Disconnect the temperature sensor wiring harness connector.
4. Remove the fuel temperature sensor from the high pressure pump.