SBM
9011-PARKTRONIC SWITCH CIRCUIT STUCK IN UP POSITION - SBM
For a complete wiring diagram Consult Diagrams/Electrical.
- When Monitored:
Continuously
- Set Condition:
When the switch is depressed for longer than 25 seconds.
Diagnostic Test
1. TEST FOR INTERMITTENT CONDITION
With the scan tool, record and erase DTC's
Operate the switch several times.
Cycle the ignition from on to off.
Turn the ignition on.
With the scan tool, read DTC's.
Does the scan tool display 9011-PARKTRONIC SWITCH CIRCUIT STUCK IN UP POSITION?
Yes
- Replace the Switch Bank Module.
- Perform BODY VERIFICATION TEST - VER 1. Verification Tests
No
- The conditions that caused this code to set are not present at this time. Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
- Perform BODY VERIFICATION TEST - VER 1. Verification Tests