Glow Plug #2 Circuit Open Circuit
Test 1 - Test 4:
Test 5 - Test 6:
SYMPTOM
P2134-GLOW PLUG #2 CIRCUIT OPEN CIRCUIT
TEST NOTE
This symptom is diagnosed using the test P1482-GLOW PLUG MODULE - EXCESS CURRENT.
POSSIBLE CAUSES
- Glow plug
- Glow plug control circuit open
- Glow plug control circuit shorted to ground
- Glow plug control circuit shorted to voltage
- Glow plug module