1-2/4-5 Solenoid Circuit
Symptom:1-2/4-5 SOLENOID CIRCUIT
1-2/4-5 SOLENOID CIRCUIT SHORT TO GROUND
Test Note: All symptoms listed above are diagnosed using the same tests.
When Monitored and Set Condition:
1-2/4-5 SOLENOID CIRCUIT
When Monitored: Always monitored with system active at each ignition cycle.
Set Condition: If the TCM detects a short to ground or battery on the solenoid control circuit, shorted solenoid, open solenoid, or an open or shorted solenoid control circuit driver in the TCM.
1-2/4-5 SOLENOID CIRCUIT SHORT TO GROUND
When Monitored: Always monitored with system active at each ignition cycle.
Set Condition: If the TCM detects a short to ground or battery on the solenoid control circuit, shorted solenoid, open solenoid, or an open or shorted solenoid control circuit driver in the TCM.
Test 1-4:
Test 5-7:
POSSIBLE CAUSES
- INTERMITTENT WIRING AND CONNECTORS
- 1-2/4-5 SOLENOID CONTROL CIRCUIT OPEN
- 1-2/4-5 SOLENOID CONTROL CIRCUIT SHORT TO GROUND
- 1-2/4-5 SOLENOID CONTROL CIRCUIT SHORT TO OTHER CIRCUITS
- 1-2/4-5 SOLENOID
- TCM - 1-2/4-5 SOLENOID CIRCUIT