Thermostatic Expansion Valve
Thermostatic Expansion Valve
Removal and Installation
1. Recover the refrigerant.
2. Detach the brake booster vacuum hose retainer from the strut tower brace.
3. NOTE: RH side of strut tower brace shown, LH similar.
Remove the 4 nuts and the strut tower brace.
- To install, tighten to 30 Nm (22 lb-ft).
4. Remove the Thermostatic Expansion Valve (TXV) fitting nut.
- Discard the O-ring seals.
- To install, tighten to 8 Nm (71 lb-in).
5. Remove the 2 TXV (Thermostatic Expansion Valve) bolts.
- To install, tighten to 8 Nm (71 lb-in).
6. Remove the TXV (Thermostatic Expansion Valve).
- Discard the O-ring seals.
7. To install, reverse the removal procedure.
- Install new O-ring seals and gasket seals.
- Add the correct amount of clean PAG oil.
8. Evacuate, leak test and charge the refrigerant system.