FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Pinpoint Test E: DTCs P0615:11, 12 and 13




Starting System

Pinpoint Test E: DTCs P0615:11, 12 and 13

Refer to Wiring Diagram Set 117, Remote Keyless Entry and Alarm for schematic and connector information. Diagrams By Number

Normal Operation

When the Start/Stop switch is pushed to the START position and released along with the brake pedal applied, the PCM receives a starter motor request signal through circuit CDC35 (BU/WH) from the Remote Function Actuator (RFA) module. The customer is no longer in the loop after the initial crank request. The PCM One-Touch Integrated Start (OTIS) feature will take over, and then the PCM will disengage the starter motor based on engine running (rpm threshold), a set crank time has been exceeded or the customer presses the Start/Stop switch again.

- DTC P0615:11 (Starter Relay Circuit: Short to Ground)- RFA (Remote Function Actuator) module circuit CDC35 (BU/WH) is shorted to ground.

- DTC P0615:12 (Starter Relay Circuit: Short to Battery)- Voltage is present on circuit CDC35 (BU/WH) to the RFA (Remote Function Actuator) module with the ignition in the OFF position.

- DTC P0615:13 (Starter Relay Circuit: Circuit Open)- RFA (Remote Function Actuator) module circuit CDC35 (BU/WH) is open.

This pinpoint test is intended to diagnose the following:

- Circuitry

- PCM

- RFA (Remote Function Actuator) module

- Smart Junction Box (SJB)

- Starter relay

PINPOINT TEST E : DTCS P0615:11, 12 AND 13

E1 CHECK DTC FAILURE TYPE

- Check the RFA (Remote Function Actuator) module DTC failure type.

Is DTC P0615:12 present?

Yes
GO to E2.

No
For DTC P0615:11, GO to E6. For DTC P0615:13 (3.5L vehicles), GO to E10. For DTC P0615:13 (3.5L Gasoline Turbocharged Direct Injection (GTDI) vehicles), GO to E11.

E2 CHECK CIRCUITS CDC35 (BU/WH) AND CE336 (GN/WH) FOR A SHORT TO BATTERY

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.

- Disconnect: Starter Relay.

- Disconnect: SJB (Smart Junction Box) C2280E.

- Disconnect: PCM C175B.

- Disconnect: RFA (Remote Function Actuator) Module C2153B.

- Measure the voltage between RFA (Remote Function Actuator) module C2153B-2, (green connector) circuit CDC35 (BU/WH), harness side and ground.





Is any voltage present?

Yes
REPAIR circuit CDC35 (BU/WH) or CE336 (GN/WH) for short to battery. TEST the system for normal operation.

No
GO to E3.

E3 CHECK THE STARTER RELAY FOR A SHORT

- Connect: Starter Relay.

- Measure the voltage between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.





Is any voltage present?

Yes
INSTALL a new starter relay. TEST the system for normal operation.

No
GO to E4.

E4 CHECK THE SJB (Smart Junction Box) FOR A SHORT

- Disconnect: Starter Relay.

- Connect: SJB (Smart Junction Box) C2280E.

- Measure the voltage between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.





Is any voltage present?

Yes
INSTALL a new SJB (Smart Junction Box). TEST the system for normal operation.

No
GO to E5.

E5 CHECK THE PCM FOR A SHORT

- Disconnect: SJB C2280E.

- Connect: PCM C175B.

- Measure the voltage between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.





Is any voltage present?

Yes
INSTALL a new PCM. TEST the system for normal operation.

No
INSTALL a new RFA (Remote Function Actuator) module. TEST the system for normal operation.

E6 CHECK CIRCUIT CDC35 (BU/WH) AND CIRCUIT CE336 (GN/WH) FOR A SHORT TO GROUND

- Disconnect: Starter Relay.

- Disconnect: SJB (Smart Junction Box) C2280E.

- Disconnect: PCM C175B.

- Disconnect: RFA (Remote Function Actuator) Module C2153B.

- Measure the resistance between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.





Is the resistance greater than 10,000 ohms?

Yes
GO to E7.

No
REPAIR circuit CDC35 (BU/WH) or CE336 (GN/WH) for short to ground. TEST the system for normal operation.

E7 ISOLATE THE STARTER RELAY

- Connect: Starter Relay.

- Measure the resistance between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.





Is the resistance greater than 10,000 ohms?

Yes
GO to E8.

No
INSTALL a new starter relay. TEST the system for normal operation.

E8 ISOLATE THE SJB (Smart Junction Box)

- Disconnect: Starter Relay.

- Connect: SJB (Smart Junction Box) C2280E.

- Measure the resistance between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.





Is the resistance greater than 10,000 ohms?

Yes
GO to E9.

No
INSTALL a new SJB (Smart Junction Box). TEST the system for normal operation.

E9 ISOLATE THE PCM

- Disconnect: SJB (Smart Junction Box) C2280E.

- Connect: PCM C175B.

- Measure the resistance between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.





Is the resistance greater than 10,000 ohms?

Yes
INSTALL a new RFA (Remote Function Actuator) module. TEST the system for normal operation.

No
INSTALL a new PCM. TEST the system for normal operation.

E10 CHECK CIRCUIT CDC35 (BU/WH) FOR AN OPEN BETWEEN RFA (Remote Function Actuator) MODULE AND PCM

- Measure the resistance between the RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and PCM C175B-9, circuit CDC35 (BU/WH), harness side.





Is the resistance less than 5 ohms?

Yes
GO to E11.

No
REPAIR circuit CDC35 (BU/WH) for an open. TEST the system for normal operation.

E11 CHECK CIRCUIT CDC35 (BU/WH) FOR AN OPEN BETWEEN RFA (Remote Function Actuator) MODULE AND PCM

- Measure the resistance between the RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and PCM C1381B-16, circuit CDC35 (BU/WH), harness side.





Is the resistance less than 5 ohms?

Yes
GO to E12.

No
REPAIR circuit CDC35 (BU/WH) for an open. TEST the system for normal operation.

E12 CHECK CIRCUIT CDC35 (BU/WH) FOR AN OPEN BETWEEN RFA (Remote Function Actuator) MODULE AND START DIODE

- Disconnect: Start Diode.

- Measure the resistance between the RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and start diode, circuit CDC35 (BU/WH), harness side.





Is the resistance less than 5 ohms?

Yes
GO to E13.

No
REPAIR circuit CDC35 (BU/WH) for an open. TEST the system for normal operation.

E13 CHECK CIRCUIT CE336 (GN/WH) FOR AN OPEN BETWEEN START DIODE AND STARTER RELAY

- Measure the resistance between the start diode, circuit CE336 (GN/WH), harness side and BJB (Battery Junction Box) starter relay pin 2, circuit CE336 (GN/WH), harness side.





Is the resistance less than 5 ohms?

Yes
GO to E14.

No
REPAIR circuit CE336 (GN/WH) for an open. TEST the system for normal operation.

E14 CHECK CIRCUIT CE336 (GN/WH) FOR AN OPEN BETWEEN STARTER RELAY SJB (Smart Junction Box)

- Measure the resistance between the BJB (Battery Junction Box) starter relay pin 2, circuit CE336 (GN/WH), harness side and SJB (Smart Junction Box) C2280E-8, circuit CE336 (GN/WH), harness side.





Is the resistance less than 5 ohms?

Yes
GO to E15.

No
REPAIR circuit CE336 (GN/WH) for an open. TEST the system for normal operation.

E15 CHECK THE STARTER RELAY

- Carry out the Starter Relay Component Test.

Did the starter relay pass the component test?

Yes
INSTALL a new RFA (Remote Function Actuator) module. TEST the system for normal operation.

No
INSTALL a new starter relay. TEST the system for normal operation.