FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Pinpoint Test E: DTC U0100:87




Remote Function Actuator (RFA) Module

Pinpoint Test E: DTC U0100:87

Normal Operation

- DTC U0100:87 (Lost Communication With ECM/PCM "A": Missing Message)- sets when the RFA (Remote Function Actuator) module is missing messages from the PCM over the High Speed Controller Area Network (HS-CAN) are missing.

This pinpoint test is intended to diagnose the following:

- Module communication

- PCM

- RFA (Remote Function Actuator) module

PINPOINT TEST E : DTC U0100:87

E1 VERIFY CUSTOMER CONCERN

- Ignition ON.

- Verify that there is an observable symptom present.

Is an observable symptom present?

Yes
GO to E2.

No
The system is operating normally at this time. The DTC may have been set due to high network traffic or intermittent fault condition.

E2 CHECK THE COMMUNICATION NETWORK

- Ignition ON.

- Enter the following diagnostic mode on the scan tool: Network Test.

- Carry out the network test.

Does the PCM pass the network test?

Yes
GO to E3.

No
REFER to Information Bus.

E3 RECHECK THE RFA (Remote Function Actuator) MODULE DTCs

- Clear the DTCs. Repeat the RFA (Remote Function Actuator) module self-test.

Is DTC U0100:87 still present?

Yes
GO to E4.

No
The system is operating correctly at this time. The DTC may have been set due to high network traffic or intermittent fault condition.

E4 CHECK FOR DTC U0100 OR DTC U0100:87 IN OTHER MODULES

NOTE: If new modules were installed prior to the DTC being set, the module configuration may be incorrectly set during Programmable Module Installation (PMI) or the PMI (Programmable Module Installation) may not have been carried out.

- Clear all DTCs.

- Ignition OFF.

- Ignition ON.

- Wait 10 seconds.

- Enter the following diagnostic mode on the scan tool: Self-Test.

- Retrieve the continuous memory DTCs from all modules.

Is DTC U0100 or DTC U0100:87 set in any other module?

Yes
INSTALL a new PCM. TEST the system for normal operation.

No
INSTALL a new RFA (Remote Function Actuator) module. REFER to Remote Function Actuator (RFA) Module . TEST the system for normal operation.