FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Pinpoint Test AX: DTC U0151:00




Instrumentation, Message Center and Warning Chimes

Pinpoint Test AX: DTC U0151:00

Normal Operation

- DTC U0151:00 (Lost Communication With Restraints Control Module: No Sub-Type Information)- sets in the Instrument Panel Cluster (IPC) if data messages received from the Restraints Control Module (RCM) over the High Speed Controller Area Network (HS-CAN) are missing. For a complete list of all network messages, refer to Information Bus.

This pinpoint test is intended to diagnose the following:

- RCM (Restraints Control Module)

- IPC (Instrument Panel Cluster)

PINPOINT TEST AX : DTC U0151:00

AX1 VERIFY THE CUSTOMER CONCERN

- Ignition ON.

- Verify that there is an observable symptom present.

Is an observable symptom present?

Yes
GO to AX2.

No
The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.

AX2 CHECK THE COMMUNICATION NETWORK

- Ignition ON.

- Enter the following diagnostic mode on the scan tool: Network Test.

- Carry out the network test.

Does the RCM (Restraints Control Module) pass the network test?

Yes
GO to AX3.

No
REFER to Information Bus.

AX3 RETRIEVE THE RECORDED DTCs FROM THE IPC (Instrument Panel Cluster) SELF-TEST

- Check for recorded DTCs from the IPC (Instrument Panel Cluster) self-test.

Is DTC U3003:16 or DTC U3003:17 recorded?

Yes
GO to Pinpoint Test BI (U3003:16) or GO to Pinpoint Test BJ (U3003:17). Pinpoint Test BI: DTC U3003:16 Pinpoint Test BJ: DTC U3003:17

No
GO to AX4.

AX4 RECHECK THE IPC (Instrument Panel Cluster) DTCs

- Clear the DTCs. Repeat the IPC (Instrument Panel Cluster) self-test.

Is DTC U0151:00 still present?

Yes
GO to AX5.

No
The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.

AX5 CHECK FOR DTC U0151:00 SET IN OTHER MODULES

- Clear all DTCs.

- Ignition OFF.

- Ignition ON.

- Wait 10 seconds.

- Enter the following diagnostic mode on the scan tool: Self-Test.

- Retrieve the continuous memory DTCs from all modules.

Is DTC U0151:00 set in the Occupant Classification System Module (OCSM)?

Yes
INSTALL a new RCM (Restraints Control Module). CLEAR the DTCs. REPEAT the self-test.

No
INSTALL a new IPC (Instrument Panel Cluster). REFER to Instrument Panel Cluster (IPC) . TEST the system for normal operation.