Blower Motor: Service and Repair
Blower Motor
Removal and Installation
1. Remove the 3 RH lower instrument panel insulator screws and the RH lower instrument panel insulator.
2. Disconnect the blower motor electrical connector.
3. Detach the 2 blower motor vent tube clips and position the tube downward to detach it from the heater core and evaporator core housing.
4. Rotate the blower motor counterclockwise to detach it from the heater core and evaporator core housing and remove the blower motor.
5. To install, reverse the removal procedure.