P0615:12
Starting System
Pinpoint Test E: DTCs P0615:11, 12 and 13
Refer to Wiring Diagram Set 117, Remote Keyless Entry and Alarm for schematic and connector information. Diagrams By Number
Normal Operation
When the Start/Stop switch is pushed to the START position and released along with the brake pedal applied, the PCM receives a starter motor request signal through circuit CDC35 (BU/WH) from the Remote Function Actuator (RFA) module. The customer is no longer in the loop after the initial crank request. The PCM One-Touch Integrated Start (OTIS) feature will take over, and then the PCM will disengage the starter motor based on engine running (rpm threshold), a set crank time has been exceeded or the customer presses the Start/Stop switch again.
- DTC P0615:11 (Starter Relay Circuit: Short to Ground)- RFA (Remote Function Actuator) module circuit CDC35 (BU/WH) is shorted to ground.
- DTC P0615:12 (Starter Relay Circuit: Short to Battery)- Voltage is present on circuit CDC35 (BU/WH) to the RFA (Remote Function Actuator) module with the ignition in the OFF position.
- DTC P0615:13 (Starter Relay Circuit: Circuit Open)- RFA (Remote Function Actuator) module circuit CDC35 (BU/WH) is open.
This pinpoint test is intended to diagnose the following:
- Circuitry
- PCM
- RFA (Remote Function Actuator) module
- Smart Junction Box (SJB)
- Starter relay
PINPOINT TEST E : DTCS P0615:11, 12 AND 13
E1 CHECK DTC FAILURE TYPE
- Check the RFA (Remote Function Actuator) module DTC failure type.
Is DTC P0615:12 present?
Yes
GO to E2.
No
For DTC P0615:11, GO to E6. For DTC P0615:13 (3.5L vehicles), GO to E10. For DTC P0615:13 (3.5L Gasoline Turbocharged Direct Injection (GTDI) vehicles), GO to E11.
E2 CHECK CIRCUITS CDC35 (BU/WH) AND CE336 (GN/WH) FOR A SHORT TO BATTERY
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- Disconnect: Starter Relay.
- Disconnect: SJB (Smart Junction Box) C2280E.
- Disconnect: PCM C175B.
- Disconnect: RFA (Remote Function Actuator) Module C2153B.
- Measure the voltage between RFA (Remote Function Actuator) module C2153B-2, (green connector) circuit CDC35 (BU/WH), harness side and ground.
Is any voltage present?
Yes
REPAIR circuit CDC35 (BU/WH) or CE336 (GN/WH) for short to battery. TEST the system for normal operation.
No
GO to E3.
E3 CHECK THE STARTER RELAY FOR A SHORT
- Connect: Starter Relay.
- Measure the voltage between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.
Is any voltage present?
Yes
INSTALL a new starter relay. TEST the system for normal operation.
No
GO to E4.
E4 CHECK THE SJB (Smart Junction Box) FOR A SHORT
- Disconnect: Starter Relay.
- Connect: SJB (Smart Junction Box) C2280E.
- Measure the voltage between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.
Is any voltage present?
Yes
INSTALL a new SJB (Smart Junction Box). TEST the system for normal operation.
No
GO to E5.
E5 CHECK THE PCM FOR A SHORT
- Disconnect: SJB C2280E.
- Connect: PCM C175B.
- Measure the voltage between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.
Is any voltage present?
Yes
INSTALL a new PCM. TEST the system for normal operation.
No
INSTALL a new RFA (Remote Function Actuator) module. TEST the system for normal operation.
E6 CHECK CIRCUIT CDC35 (BU/WH) AND CIRCUIT CE336 (GN/WH) FOR A SHORT TO GROUND
- Disconnect: Starter Relay.
- Disconnect: SJB (Smart Junction Box) C2280E.
- Disconnect: PCM C175B.
- Disconnect: RFA (Remote Function Actuator) Module C2153B.
- Measure the resistance between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.
Is the resistance greater than 10,000 ohms?
Yes
GO to E7.
No
REPAIR circuit CDC35 (BU/WH) or CE336 (GN/WH) for short to ground. TEST the system for normal operation.
E7 ISOLATE THE STARTER RELAY
- Connect: Starter Relay.
- Measure the resistance between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.
Is the resistance greater than 10,000 ohms?
Yes
GO to E8.
No
INSTALL a new starter relay. TEST the system for normal operation.
E8 ISOLATE THE SJB (Smart Junction Box)
- Disconnect: Starter Relay.
- Connect: SJB (Smart Junction Box) C2280E.
- Measure the resistance between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.
Is the resistance greater than 10,000 ohms?
Yes
GO to E9.
No
INSTALL a new SJB (Smart Junction Box). TEST the system for normal operation.
E9 ISOLATE THE PCM
- Disconnect: SJB (Smart Junction Box) C2280E.
- Connect: PCM C175B.
- Measure the resistance between RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and ground.
Is the resistance greater than 10,000 ohms?
Yes
INSTALL a new RFA (Remote Function Actuator) module. TEST the system for normal operation.
No
INSTALL a new PCM. TEST the system for normal operation.
E10 CHECK CIRCUIT CDC35 (BU/WH) FOR AN OPEN BETWEEN RFA (Remote Function Actuator) MODULE AND PCM
- Measure the resistance between the RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and PCM C175B-9, circuit CDC35 (BU/WH), harness side.
Is the resistance less than 5 ohms?
Yes
GO to E11.
No
REPAIR circuit CDC35 (BU/WH) for an open. TEST the system for normal operation.
E11 CHECK CIRCUIT CDC35 (BU/WH) FOR AN OPEN BETWEEN RFA (Remote Function Actuator) MODULE AND PCM
- Measure the resistance between the RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and PCM C1381B-16, circuit CDC35 (BU/WH), harness side.
Is the resistance less than 5 ohms?
Yes
GO to E12.
No
REPAIR circuit CDC35 (BU/WH) for an open. TEST the system for normal operation.
E12 CHECK CIRCUIT CDC35 (BU/WH) FOR AN OPEN BETWEEN RFA (Remote Function Actuator) MODULE AND START DIODE
- Disconnect: Start Diode.
- Measure the resistance between the RFA (Remote Function Actuator) module C2153B-2, circuit CDC35 (BU/WH), harness side and start diode, circuit CDC35 (BU/WH), harness side.
Is the resistance less than 5 ohms?
Yes
GO to E13.
No
REPAIR circuit CDC35 (BU/WH) for an open. TEST the system for normal operation.
E13 CHECK CIRCUIT CE336 (GN/WH) FOR AN OPEN BETWEEN START DIODE AND STARTER RELAY
- Measure the resistance between the start diode, circuit CE336 (GN/WH), harness side and BJB (Battery Junction Box) starter relay pin 2, circuit CE336 (GN/WH), harness side.
Is the resistance less than 5 ohms?
Yes
GO to E14.
No
REPAIR circuit CE336 (GN/WH) for an open. TEST the system for normal operation.
E14 CHECK CIRCUIT CE336 (GN/WH) FOR AN OPEN BETWEEN STARTER RELAY SJB (Smart Junction Box)
- Measure the resistance between the BJB (Battery Junction Box) starter relay pin 2, circuit CE336 (GN/WH), harness side and SJB (Smart Junction Box) C2280E-8, circuit CE336 (GN/WH), harness side.
Is the resistance less than 5 ohms?
Yes
GO to E15.
No
REPAIR circuit CE336 (GN/WH) for an open. TEST the system for normal operation.
E15 CHECK THE STARTER RELAY
- Carry out the Starter Relay Component Test.
Did the starter relay pass the component test?
Yes
INSTALL a new RFA (Remote Function Actuator) module. TEST the system for normal operation.
No
INSTALL a new starter relay. TEST the system for normal operation.