FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Pinpoint Test AA: The Door/Hood Ajar Warning Indicator Is Never/Always On




Instrumentation, Message Center and Warning Chimes

Pinpoint Test AA: The Door/Hood Ajar Warning Indicator Is Never/Always On (Fusion Non-Hybrid)

Normal Operation

The Instrument Panel Cluster (IPC) receives the door/hood ajar status for the LH front door, RH front door, LH rear door, the RH rear door and hood from the Smart Junction Box (SJB) over the Medium Speed Controller Area Network (MS-CAN) communication bus. When the IPC (Instrument Panel Cluster) receives a message from the SJB (Smart Junction Box) that the hood or one or more doors is open or ajar, the IPC (Instrument Panel Cluster) turns on the door/hood ajar warning indicator.

If the door/hood ajar status message is missing for less than 5 seconds, the door/hood ajar warning indicator remains in the last indication mode (on or off) based upon the last known good message received. If the door/hood ajar status message is missing for more than 5 seconds, the IPC (Instrument Panel Cluster) sets DTC U0140:00 and defaults the door/hood ajar warning indicator on.

NOTE: If DTC U0140:00 is set in the SJB (Smart Junction Box) , other symptoms may also be present in the IPC (Instrument Panel Cluster) such as high beam indicator, RH/LH turn indicators, instrument panel backlighting and Tire Pressure Monitoring System (TPMS).

This pinpoint test is intended to diagnose the following:

- Interior lighting concern

- SJB (Smart Junction Box)

- IPC (Instrument Panel Cluster)

PINPOINT TEST AA : THE DOOR/HOOD AJAR WARNING INDICATOR IS NEVER/ALWAYS ON (FUSION NON-HYBRID)

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.

AA1 CHECK THE INTERIOR LIGHTING OPERATION

- Open and close each door while monitoring the courtesy lamps.

Do the courtesy lamps operate correctly with each door?

Yes
GO to AA2.

No
REFER to Lighting and Horns.

AA2 CHECK THE HOOD AJAR SWITCH STATUS PID

- Ignition ON.

- Enter the following diagnostic mode on the scan tool: SJB (Smart Junction Box) DataLogger.

- Select the SJB (Smart Junction Box) hood ajar switch PID (HOOD_SW). Monitor the PID with the hood closed and open.

Does the PID agree with the status of the hood?

Yes
GO to AA3
No
REFER to Antitheft and Alarm Systems to diagnose the hood ajar switch circuit.

AA3 CARRY OUT THE IPC (Instrument Panel Cluster) DOOR/HOOD AJAR WARNING INDICATOR ACTIVE COMMAND USING THE SCAN TOOL

- Ignition ON.

- Enter the following diagnostic mode on the scan tool: IPC (Instrument Panel Cluster) DataLogger.

- Select the IPC (Instrument Panel Cluster) door ajar warning indicator (DOOR_AJAR) active command. Command the door ajar warning indicator on and off while observing the door ajar warning indicator.

Does the door ajar warning indicator illuminate when commanded on, and turn off when commanded off?

Yes
GO to AA4.

No
INSTALL a new IPC (Instrument Panel Cluster). REFER to Instrument Panel Cluster (IPC) . TEST the system for normal operation.

AA4 RETRIEVE THE RECORDED DTCs FROM THE CONTINUOUS IPC (Instrument Panel Cluster) SELF-TEST

- Check for recorded IPC (Instrument Panel Cluster) DTCs from the continuous self-test.

Is DTC U0140:00 recorded?

Yes
GO to Pinpoint Test BM. Pinpoint Test BM: DTC U0140:00

No
GO to AA5.

AA5 RETRIEVE THE RECORDED DTCs FROM THE SJB (Smart Junction Box) SELF-TEST

- Check for recorded DTCs from the SJB (Smart Junction Box) self-test.

Are any SJB (Smart Junction Box) DTCs recorded?

Yes
REFER to the Diagnostic Trouble Code (DTC) Chart in Body Control Systems. Body Control Systems

No
INSTALL a new SJB (Smart Junction Box). TEST the system for normal operation.