Pinpoint Test O: The Autolock Does Not Operate Correctly
Handles, Locks, Latches and Entry Systems
Pinpoint Test O: The Autolock Does Not Operate Correctly
Normal Operation
The Smart Junction Box (SJB) energizes the lock relay based upon input from the ajar switches, the Transmission Range (TR) sensor, and the vehicle speed signal. The SJB (Smart Junction Box) locks the doors when the following conditions are met:
- All the doors are closed
- The ignition switch is in the ON position
- The vehicle is shifted into any gear putting the vehicle in motion
- The vehicle attains a speed greater than 20 km/h (12 mph)
NOTE: The autolock feature is not available on vehicles equipped with a manual transaxle.
This pinpoint test is intended to diagnose the following:
- Ignition switch
- Door ajar switches
- Vehicle speed signal
- TR (Transmission Range) sensor
- SJB (Smart Junction Box)
PINPOINT TEST O : THE AUTOLOCK DOES NOT OPERATE CORRECTLY
O1 CHECK THE AUTOLOCKS CONFIGURATION
- Check to see if the autolocks are enabled. Refer to Autolock and Auto-Unlock Programming .
Are the autolocks enabled?
Yes
GO to O2.
No
ENABLE the autolocks. REFER to Autolock and Auto-Unlock Programming . TEST the system for normal operation.
O2 CHECK THE COURTESY LAMP OPERATION
- Open and close each door while observing the courtesy lamp operation.
Do the courtesy lamps operate correctly?
Yes
GO to O3.
No
REFER to Lighting and Horns.
O3 CHECK THE SJB (Smart Junction Box) IGNITION STATUS PID
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: SJB (Smart Junction Box) DataLogger.
- Monitor the SJB (Smart Junction Box) PID (IGN_R_ECU).
Does the ignition status PID indicate ON?
Yes
GO to O4.
No
REFER to Steering Column to continue diagnosis of the ignition switch.
O4 CHECK THE VEHICLE SPEED OPERATION
- Check the operation of the speedometer.
Does the speedometer operate correctly?
Yes
GO to O5.
No
REFER to Instrument Panel, Gauges and Warning Indicators.
O5 RETRIEVE THE RECORDED SJB (Smart Junction Box) DTCs FROM THE CONTINUOUS SELF-TESTS
- Check for recorded SJB (Smart Junction Box) DTCs from the continuous self-tests.
Is DTC U0155 recorded?
Yes
REFER to Information Bus.
No
GO to O6.
O6 CHECK FOR CORRECT SJB (Smart Junction Box) OPERATION
- Disconnect all the SJB (Smart Junction Box) connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB (Smart Junction Box) connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
Is the concern still present?
Yes
INSTALL a new SJB (Smart Junction Box). TEST the system for normal operation.
No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.