Pinpoint Test E: The Flash-To-Pass Feature Is Inoperative
Headlamps
Pinpoint Test E: The Flash-To-Pass Feature Is Inoperative
Normal Operation
The Body Control Module (BCM) sends a voltage signal to the multifunction switch to monitor for a flash-to-pass feature request. The multifunction switch routes the voltage signal to ground when placed in the FLASH-TO-PASS position. When the headlamps are on and the BCM (Body Control Module) detects a request for the flash-to-pass feature, the BCM (Body Control Module) activates the high beams.
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Multifunction switch
- BCM (Body Control Module)
PINPOINT TEST E : THE FLASH-TO-PASS FEATURE IS INOPERATIVE
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
E1 VERIFY THE HIGH BEAM HEADLAMP OPERATION
- Ignition ON.
- Place the headlamp switch in the HEADLAMPS ON position.
- Place the multifunction switch in the HIGH BEAM position while observing the headlamps.
Do the high beams illuminate?
Yes
GO to E2.
No
GO to Pinpoint Test B Pinpoint Test B: One Or Both High Beams Are Inoperative.
E2 BYPASS THE MULTIFUNCTION SWITCH
- Place the headlamp switch in the OFF position.
- Ignition OFF.
- Disconnect: Multifunction Switch C202A.
- Ignition ON.
- Connect a fused jumper wire between the multifunction switch C202A-5, circuit CLF27 (GN/BN), harness side and the multifunction switch C202A-9, circuit GD115 (BK/GY), harness side.
Do the high beams illuminate?
Yes
REMOVE the jumper wire. INSTALL a new multifunction switch. TEST the system for normal operation.
No
REMOVE the jumper wire. GO to E3.
E3 CHECK THE FLASH-TO-PASS INPUT CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: BCM (Body Control Module) C2280E.
- Measure the resistance between the multifunction switch C202A-5, circuit CLF27 (GN/BN), harness side and the BCM (Body Control Module) C2280E-22, circuit CLF27 (GN/BN), harness side.
Is the resistance less than 5 ohms?
Yes
GO to E4.
No
REPAIR circuit CLF27 (GN/BN) for an open. TEST the system for normal operation.
E4 CHECK FOR CORRECT BCM (Body Control Module) OPERATION
- Disconnect all the BCM (Body Control Module) connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the BCM (Body Control Module) connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
Is the concern still present?
Yes
INSTALL a new BCM (Body Control Module). TEST the system for normal operation.
No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.