Pinpoint Test D: The Roof Opening Panel is Noisy During Operation
Roof Opening Panel
Pinpoint Test D: The Roof Opening Panel is Noisy During Operation
Normal Operation
The roof opening panel operates smoothly and quietly while opening and closing.
This pinpoint test is intended to diagnose the following:
- Roof opening panel alignment
- Roof opening panel frame
- Roof opening panel shield
- Roof opening panel module
PINPOINT TEST D : THE ROOF OPENING PANEL IS NOISY DURING OPERATION
D1 CHECK THE ROOF OPENING PANEL FOR OBSTRUCTIONS OR DAMAGE
- Check the roof opening panel for any obstructions and damage.
Are there any obstructions and/or damage?
Yes
REMOVE all obstructions. REPAIR any damage. If the damage cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel Roof Opening Panel. TEST the system for normal operation.
No
GO to D2.
D2 CHECK THE ROOF OPENING PANEL OPERATION
- Check the roof opening panel during operation.
Is the roof opening panel glass loose or incorrectly aligned?
Yes
ALIGN the roof opening panel. REFER to Roof Opening Panel Alignment Adjustments. TEST the system for normal operation.
No
GO to D3.
D3 CHECK THE ROOF OPENING PANEL TRACKS
- Open the roof.
- Check the roof opening panel tracks for obstructions and damage.
Are the roof opening panel tracks OK?
Yes
GO to D4.
No
REMOVE all obstructions and REPAIR any damage. If the roof opening panel tracks cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel Roof Opening Panel. TEST the system for normal operation.
D4 CHECK THE ROOF OPENING PANEL SHIELD
- Check the roof opening panel shield for correct movement.
Is the roof opening panel shield moving correctly?
Yes
GO to D5.
No
REMOVE and REINSTALL the roof opening panel shield. If necessary, INSTALL a new roof opening panel shield. REFER to Roof Opening Panel Shield Roof Opening Panel Shield. TEST the system for normal operation.
D5 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES
- Check the roof opening panel lifter assemblies for obstructions and damage.
Are the roof opening panel lifter assemblies OK?
Yes
GO to D6.
No
REMOVE all obstructions and REPAIR any damage. If the roof opening panel lifter assemblies cannot be repaired, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel Roof Opening Panel. TEST the system for normal operation.
D6 CHECK THE ROOF OPENING PANEL MODULE
- Remove the roof opening panel module and leave the electrical connector connected.
- Operate the roof opening panel to the fully OPEN and CLOSED position.
Does the module make excessive noise?
Yes
INSTALL a new roof opening panel module. REFER to Roof Opening Panel Motor Roof Opening Panel Motor. TEST the system for normal operation.
No
REINSTALL the roof opening panel module. TEST the system for normal operation. If the roof opening panel is still noisy, INSTALL a new roof opening panel frame. REFER to Roof Opening Panel. If the roof opening panel is no longer noisy, the system is operating correctly. The concern may have been caused by an incorrectly installed roof opening panel motor.