Air Cleaner Outlet Pipe




Air Cleaner Outlet Pipe

Removal and Installation

1. Disconnect the crankcase ventilation tube-to-Air Cleaner (ACL) outlet pipe quick connect coupling. For additional information, refer to Fuel Delivery and Air Induction.

2. Remove the vacuum tube to ACL outlet pipe.

3. Loosen the clamp and remove the ACL outlet pipe from the Throttle Body (TB).
- To install, tighten to 4 Nm (35 lb-in).

4. Loosen the ACL outlet pipe-to-ACL housing cover clamp.
- Remove the ACL outlet pipe.

- To install, tighten to 4 Nm (35 lb-in).

5. NOTE: The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.

To install, reverse the removal procedure.