Blower Motor Speed Control
BLOWER MOTOR SPEED CONTROLRemoval and Installation
1. Remove the RH lower instrument panel insulator.
2. Remove the blower motor speed control.
1 Disconnect the vacuum line.
2 Disconnect the electrical connectors.
3 Remove the 2 screws and the blower motor speed control.
3. To install, reverse the removal procedure.