Test D: No Power In Start
Pinpoint Test D: No Power in STARTD1:
D1-D2:
D3-D4:
Normal Operation
The ignition switch START circuit provides greater than 10 volts through circuits 1522 (DG) and 1044 (WH/YE) to the smart Junction box (SJB) when the key is in the START position.
Possible Causes
^ Circuit 1044 (WH/YE) open or short to ground
^ Circuit 1522 (DG) open or short to ground
^ Ignition switch
^ SJB