Test Q: The LH Turn Indicator Is Never on
PINPOINT TEST Q: THE LH TURN INDICATOR IS NEVER ONQ1-Q3:
Q4:
Normal Operation
The LH turn indicator bulb is powered through circuit 1393 (LB/RD) when the multifunction switch is placed in the LH turn signal position. The LH turn indicator bulb is grounded through the instrument cluster bulb ground circuit 1205 (BK).
Possible Causes
- circuit 1393 (LB/RD) open
- circuit 1205 (BK) open
- multifunction switch
- instrument cluster