Torque Converter Impeller to Pump Stator Interference Check
Torque Converter Impeller to Pump Stator Interference Check1. If equipped, remove the drain plug and drain the fluid from the torque converter.
2. Install fluid pump support into the torque converter. Engage splines of the one-way clutch inner race with the mating splines of the overdrive pump support.
3. While holding the fluid pump support stationary, rotate the torque converter clockwise and counterclockwise. The torque converter should rotate freely with no signs of scraping. If there are signs of scraping, install a new or remanufactured torque converter.