Transfer Case Draining and Filling
Transfer Case Draining and Filling,1. Remove the drain plug and drain the fluid.
Clean and install the drain plug after fluid is drained.
2. CAUTION: Incorrect fluid fill can result in transfer case failure.
NOTE: Clean the area around the fill plug.
Remove the fill plug, and fill the transfer case.
^ The fluid must be just below the fill plug hole. Because you can reach the fluid with a finger does not mean the fluid is at the correct level. Make sure the fluid is level with the filler opening for the correct fluid level.
^ The total transfer case fill capacity is 1.25 Liter (2.6 pints).
3. Install the fill plug.