FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Alternator Brush: Service and Repair

REMOVAL
1. Remove the generator.





2. Remove the generator brush and terminal holder and the voltage regulator.
1 Remove the four voltage regulator screws.
2 Remove the generator brush and terminal holder and the voltage regulator.





3. Separate the generator brush and terminal holder from the voltage regulator.
1 Remove the screw cap.
2 Remove the two generator brush and terminal holder screws.
3 Separate the generator brush and terminal holder from the voltage regulator.

INSTALLATION





1. Install the brush and terminal holder on the voltage regulator.
1 Position the brush and terminal holder on the voltage regulator.
2 Install the two generator brush and terminal holder screws.
3 Install the screw cap.

CAUTION: Make sure screw cap is installed over Test Terminal A to prevent accidental shorting of the battery positive connection.





2. Install the generator brush and terminal holder and the voltage regulator.
1 Depress the brushes and insert a wire to hold the brushes during installation.
2 Position the generator brush and terminal holder and the voltage regulator.
3 Install the four voltage regulator screws.
4 Remove the wire.
3. Install the generator.