Alternator Brush: Service and Repair
REMOVAL1. Remove the generator.
2. Remove the generator brush and terminal holder and the voltage regulator.
1 Remove the four voltage regulator screws.
2 Remove the generator brush and terminal holder and the voltage regulator.
3. Separate the generator brush and terminal holder from the voltage regulator.
1 Remove the screw cap.
2 Remove the two generator brush and terminal holder screws.
3 Separate the generator brush and terminal holder from the voltage regulator.
INSTALLATION
1. Install the brush and terminal holder on the voltage regulator.
1 Position the brush and terminal holder on the voltage regulator.
2 Install the two generator brush and terminal holder screws.
3 Install the screw cap.
CAUTION: Make sure screw cap is installed over Test Terminal A to prevent accidental shorting of the battery positive connection.
2. Install the generator brush and terminal holder and the voltage regulator.
1 Depress the brushes and insert a wire to hold the brushes during installation.
2 Position the generator brush and terminal holder and the voltage regulator.
3 Install the four voltage regulator screws.
4 Remove the wire.
3. Install the generator.