B5
B5 CHECK THE RELAY COIL- KEY "OFF."
- Disconnect the red brake warning indicator relay.
Red Brake Warning Indicator Relay Coil Terminals:
- Check the resistance between the red brake warning indicator relay coil terminals 1 and 2.
Is the resistance between 50 and 70 ohms?
> Yes
Replace the Electronic Hydraulic Control Unit (EHCU). B17
> No
Replace the red brake warning indicator relay. B17