PC5
PC5 CHECK ELECTRONIC HYDRAULIC CONTROL UNIT (EHCU) GROUND- Key "OFF."
- Disconnect the battery negative cable.
- Check the resistance between the battery negative cable and the EHCU ground eyelet.
Is the resistance less than 1 ohm?
> Yes
Perform Pinpoint Test N. N
> No
Repair open in circuit 57 (BK). Repeat Pre-Check PC4. PC4