Shift Interlock Cable: Adjustments
1. Move select lever to Reverse position, then clamp shift lock cable.2. Connect shift lock cable to select lever assembly and temporarily tighten nut.
3. Slide shift lock cable so distance between select lever assembly's detent pin and end of shift lock cable (distance A) is 0.04-0.15 inch, Fig.5.