FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Light Does Not Switch Off

Battery Connections:





System Operation and Code Output
This diagnostic trouble code is output when a short to ground occurs in the harness between the light and the SRS-ECU while the SRS-ECU is monitoring the SRS warning light and the light is ON.

Probable Cause
- Malfunction of harnesses or connectors
- Malfunction of SRS-ECU

Diagnostic Chart:




Testing - Corrective Action


Caution: Turn the ignition key to the "LOCK" position, disconnect the negative battery cable and tape the terminal. Wait at least 60 seconds after disconnecting the battery cable before doing any further work. (Refer to Service Precautions)