Wastegate Solenoid: Service and Repair
Waste Gate Solenoid Valve Location:
Removal
1. Disconnect the electrical harness connector.
2. Disconnect the vacuum hoses.
3. Remove the solenoid valve.
Installation
Follow the removal procedures in reverse order.