Chart No. 6-2, Inhibitor Switch Wiring Circuit A/T
The inhibitor switch also functions as the neutral safety switch for the starter. If the selector handle is moved to the N position during constant speed, a cancel signal is sent to the control unit, cancelling constant speed travel.Measure check inhibitor switch supply voltage, terminal No. 1. Voltage should measure 12 volts at all times.