Input Shaft Seal - Installation
INSTALLATION
NOTE: Seal should be set to 4mm (.16 in) sub-flush.
1. Install the input shaft seal (2) 4mm (.16 in) sub-flush using Installer MD-998323 (1).
2. Install the transmission DMT6 Manual Transmission - Installation.