Installation
2.7L
1. Clean MAP sensor mounting hole at intake manifold.
2. Check MAP sensor O-ring seal for cuts or tears.
3. Position sensor into intake manifold.
4. Rotate sensor 1/4 turn clockwise for installation.
5. Connect electrical connector to sensor.
6. Lock electrical connector.
7. Connect negative battery cable.