Occupant Restraint Controller - Installation






INSTALLATION





NOTE: Make sure to leave the ORC covering panel (1) is in place. Failure to do so may result in false ORC DTC's. The covering prevents the shifter cables from smacking on the top of the ORC and possibly setting a false code.

1. Make sure to lift up on the ORC covering panel to insert the ORC.




2. Connect the two ORC connectors (4) and ensure that the connectors are engaged.

3. Position ORC (arrow pointing forward) on the console floor bracket and mounting studs (1).

4. Install the three ORC retaining nuts (2) and tighten to 9 Nm (79.5 in. lbs.).




5. Install floor shifter bezel (1).

WARNING: Do not connect the battery negative cable. Personal injury or death may result if the system test is not performed first.