P0953
Symptom:P0953-AUTOSTICK INPUT CIRCUIT HIGH
When Monitored:
The AutoStick circuit is checked every.007 seconds, with the ignition on, and in both AutoStick and non-AutoStick modes.
Set Condition:
When the monitored circuit voltage rises above 4.8 volts.
Test 1-2:
Test 3-5:
Test 6-8:
POSSIBLE CAUSES
- AUTOSTICK SWITCH GROUND CIRCUIT OPEN
- AUTOSTICK/OD OFF MUX INPUT CIRCUIT OPEN
- AUTOSTICK/OD OFF MUX INPUT CIRCUIT SHORT TO VOLTAGE
- AUTOSTICK SWITCH
- POWERTRAIN CONTROL MODULE
- INTERMITTENT WIRING AND CONNECTORS