FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Ambient Temperature Sensor / Switch HVAC: Testing and Inspection

AMBIENT TEMPERATURE SENSOR TEST
1. Turn the ignition OFF.
2. Disconnect and isolate the battery negative cable.
3. Disconnect the ambient temperature sensor harness connector.
4. Measure the resistance of the ambient temperature sensor using the following values:

0 degrees C (32 degrees F) Sensor Resistance = 29.33 - 35.99 Kilohms
10 degrees C (50 degrees F) Sensor Resistance = 17.99 - 21.81 Kilohms
20 degrees C (68 degrees F) Sensor Resistance = 11.37 - 13.61 Kilohms
25 degrees C (77 degrees F) Sensor Resistance = 9.12 - 10.86 Kilohms
30 degrees C (86 degrees F) Sensor Resistance = 7.37 - 8.75 Kilohms
40 degrees C (104 degrees F) Sensor Resistance = 4.90 - 5.75 Kilohms

The sensor resistance should read between these min/max values. If the resistance value is OK, refer to the Wiring Diagrams to test the Signal and Ground circuits. If the resistance values are not OK, replace the Sensor.