P0563
Tests 1 - 2:
Tests 3 - 7:
Tests 8:
SYMPTOM
P0563-BATTERY VOLTAGE HIGH
WHEN MONITORED
The engine running. The engine speed greater than 380 RPM.
SET CONDITION
Battery voltage is 1 volt greater than desired system voltage. One Trip Fault
POSSIBLE CAUSES
- Generator field control circuit shorted to ground
- Generator field control circuit open
- Generator field ground circuit open
- Intermittent condition
- Generator operation
- Generator field control circuit shorted to battery voltage
- PCM