ACM Driver Squib Shorted to Ground (Active)
Test 1:
Tests 2 - 3:
Tests 4 - 5:
SYMPTOM
ACM, DRIVER SQUIB SHORT TO GROUND - ACTIVE
WHEN MONITORED
When the ignition is ON, the ACM monitors the voltage of the Driver Squib circuits.
SET CONDITION
The ACM has detected a short to ground in the Driver Squib circuits.
POSSIBLE CAUSES
- Driver airbag short to ground
- Clockspring, circuits short to ground
- Driver airbag line 1 short to ground
- Driver airbag line 2 short to ground
- ACM, driver airbag short to ground