FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

ACM Driver Squib Circuit Open (Active)

Test 1:




Tests 2 - 3:




Tests 4 - 5:




SYMPTOM
ACM, DRIVER SQUIB CIRCUIT OPEN - ACTIVE

WHEN MONITORED
When the ignition is ON, the ACM monitors the resistance of the Driver Squib circuits every.

SET CONDITION
The ACM has detected an open circuit or high resistance in the Driver Squib circuits.

POSSIBLE CAUSES
- Driver airbag open
- Clockspring, driver airbag circuits open
- Driver airbag line 2 open
- Driver airbag line 1 open
- ACM, driver airbag circuit open