Synchronizer
DISASSEMBLYPlace synchronizer in a clean shop towel and wrap. Press on inner hub. Carefully open up shop towel and remove springs, balls, keys, hub, and sleeve.
ASSEMBLY
1. Position synchronizer hub onto a suitable holding fixture (input shaft). The synchronizer hubs are directional. The hubs must be installed with the U facing upward.
Fig. 125:
2. Install springs into hub slot (Fig. 125).
3. Insert key into hub and spring.
Fig. 126:
4. Apply petroleum jelly to the hole in the key. Insert balls into each key (Fig. 126).
Fig. 127:
5. Slide sleeve over the hub and depress balls as you carefully slip the sleeve into position (Fig. 127).
Fig. 128:
6. Line up stop ring tang over the keys in the hub (Fig. 128). Install stop rings. Center the keys and balls by pushing on both stop rings.