MAP / IAT Sensor
MAP/IAT Sensor:
The MAP/IAT sensor attaches to the intake manifold plenum.
REMOVAL
1. Remove the negative battery cable.
2. Disconnect the electrical connector from the MAP/IAT sensor.
3. Remove sensor mounting screws.
4. Remove sensor.
INSTALLATION
1. Insert sensor into intake manifold while making sure not to damage O-ring seal.
2. Tighten mounting screws to 2 Nm (20 in. lbs) torque for plastic manifold and 3 Nm (30 in. lbs.) for aluminum manifold.
3. Attach electrical connector to sensor.
4. Install the negative battery cable.